Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Sci Rep ; 14(1): 9984, 2024 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-38693352

RESUMEN

The aim of this work is to quantitatively assess the wavefront phase of keratoconic eyes measured by the ocular aberrometer t·eyede (based on WaveFront Phase Imaging Sensor), characterized by a lateral resolution of 8.6 µm without requiring any optical element to sample the wavefront information. We evaluated the parameters: root mean square error, Peak-to-Valley, and amplitude of the predominant frequency (Fourier Transform analysis) of a section of the High-Pass filter map in keratoconic and healthy cohorts. Furthermore, we have analyzed keratoconic eyes that presented dark-light bands in this map to assess their period and orientation with the Fourier Transform. There are significant statistical differences (p value < 0.001) between healthy and keratoconic eyes in the three parameters, demonstrating a tendency to increase with the severity of the disease. Otherwise, the quantification of the bands reveals that the width is independent of eye laterality and keratoconic stage as orientation, which tends to be oblique. In conclusion, the quantitative results obtained with t·eyede could help to diagnose and monitor the progression of keratoconus.


Asunto(s)
Queratocono , Queratocono/diagnóstico por imagen , Queratocono/diagnóstico , Humanos , Adulto , Femenino , Masculino , Topografía de la Córnea/métodos , Adulto Joven , Aberrometría/métodos , Córnea/diagnóstico por imagen , Córnea/patología , Análisis de Fourier
2.
Ophthalmol Ther ; 12(3): 1569-1582, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-36856979

RESUMEN

INTRODUCTION: This study performs optical aberration assessment in patients using a novel ultra-high-resolution device. The objective of this study is to analyze optical aberrations, especially the very high order wavefront (more than 10th order of Zernike coefficients), and compare between keratoconus and healthy patients. METHODS: In this cross-sectional study, we analyzed 43 eyes from 25 healthy patients and 43 eyes from 27 patients with keratoconus using corneal tomography and a very high-resolution (8.55 µm) aberrometer prototype (T-eyede) outfitted with a sensor originally developed for use in the field of astrophysics. Corneal aberration values were assessed using an optical model built with Zemax optical software, while ocular aberrations were assessed using T-eyede. In addition, image-processing analysis was performed of the wavefront phase, creating a high-pass filter map. RESULTS: We found lower values for ocular aberrations than corneal aberrations in both groups (p < 0.001). Specifically, we found a reduction in primary astigmatism (0.145 µm) and primary coma (0.017 µm). Also, the keratoconus group showed significantly higher wavefront aberration values compared with controls (p < 0.001). An analysis of the high-pass filter map revealed 2 contrasting results: one smooth or clear, while the other presented a banding pattern. Almost all in the control group (95%) showed the first pattern, while 77% of the keratoconus group showed a banding pattern on the filtered map (chi-squared test, p < 0.001). CONCLUSION: This device provides reliable, precise measurements of ocular aberrations that correlate well with corneal aberrations. Furthermore, the extraordinary high-resolution measurements revealed unprecedented micro changes in the wavefront phase of patients with keratoconus that varied with disease stage. These findings could lead to new screening or follow-up methods.

3.
Entropy (Basel) ; 22(6)2020 Jun 18.
Artículo en Inglés | MEDLINE | ID: mdl-33286450

RESUMEN

The optimum pressure ratio for the stages of a multistage compression process is calculated with a well known formula that assigns an equal ratio for all stages, based on the hypotheses that all isentropic efficiencies are also equal. Although the derivation of this formula for two stages is relatively easy to find, it is more difficult to find for any number of stages, and the examples that are found in the literature employ complex mathematical methods. The case when the stages have different isentropic efficiencies is only treated numerically. Here, a step by step derivation of the general formula and of the formula for different stage efficiencies are carried out using Lagrange multipliers. A main objective has been to maintain the engineering considerations explicitly, so that the hypotheses and reasoning are clear throughout, and will enable the readers to generalise or adapt the methodology to specific problems. As the actual design of multistage compression processes frequently meet engineering restrictions, a practical example has been developed where the previous formulae have been applied to the design of a multistage compression plant with reciprocating compressors. Special attention has been put into engineering considerations.

4.
Sci Rep ; 8(1): 8520, 2018 06 04.
Artículo en Inglés | MEDLINE | ID: mdl-29867132

RESUMEN

Amoebae of the genus Acanthamoeba are ubiquitous protists that have been isolated from many sources such as soils, water and the air. They are responsible for infections including fatal encephalitis and a severe keratitis in humans. To date, there is no satisfactorily effective therapeutic agent against this pathogen and the infections it causes are exacerbated by the existence of a resistant cyst stage produced by this amoeba. As dry eye syndrome is a risk factor for Acanthamoeba keratitis, we aimed to evaluate the anti-Acanthamoeba activity of a variety of proprietary eye drops intended to treat dry eye syndrome. From the nine eye drop formulations tested, "Systane Ultra" was determined to be the most active against all tested Acanthamoeba strains. During our investigations into the mode of action of Systane Ultra, we discovered that it decreases mitochondrial membrane potential and ATP levels, induces chromatin condensation, and increases the permeability of the plasma-membrane.


Asunto(s)
Acanthamoeba/metabolismo , Amebiasis/tratamiento farmacológico , Amebicidas/farmacología , Síndromes de Ojo Seco/tratamiento farmacológico , Queratosis/tratamiento farmacológico , Soluciones Oftálmicas/farmacología , Síndromes de Ojo Seco/parasitología , Humanos , Queratosis/parasitología
5.
Acta Parasitol ; 63(2): 393-396, 2018 Jun 26.
Artículo en Inglés | MEDLINE | ID: mdl-29654681

RESUMEN

Pathogenic strains of Acanthamoeba are causative agents of a sight-threatening infection of the cornea known as Acanthamoeba keratitis (AK) which mainly affects contact lens wearers and it is commonly related to poor hygiene of contact lenses and their cases. Moreover, treatment of AK is complex due to the existence of a highly resistant cyst stage and if not diagnosed early has poor prognosis, leading to blindness and/or keratoplasty. Even though AK is increasing worldwide as well as awareness among patients and clinicians, it is still a poorly studied pathogen. Additionally, a remaining question to be answered is whether these opportunistic pathogens are present in the ocular surface of healthy contact lens wearers since they are the main group at risk.In order to carry out this study, sterile Schirmer strip tests were collected from a group of individuals all of them contact lens wearers who were attending a local ophthalmology clinic in Tenerife, Canary Islands, Spain. The collected samples (100 eyes of 50 patients) were cultured in 2% Non-Nutrient Agar (NNA) plates and positive plates (16) were then cultured in axenic conditions for further analyses. Molecular analysis classified all isolated strains belonged to Acanthamoeba genotype T4 and osmotolerance and thermotolerance assays revealed that all strains were potentially pathogenic. In conclusion, the ocular surface of contact lens wearers included in this study was colonized by potentially pathogenic strains of Acanthamoeba and should be considered as a risk for AK infection in this region and worldwide.


Asunto(s)
Acanthamoeba/aislamiento & purificación , Amebiasis/epidemiología , Lentes de Contacto/parasitología , Ojo/parasitología , Acanthamoeba/genética , Acanthamoeba/patogenicidad , Queratitis por Acanthamoeba/epidemiología , Queratitis por Acanthamoeba/parasitología , Adulto , Amebiasis/diagnóstico , Amebiasis/parasitología , Animales , Cultivo Axénico , Genotipo , Humanos , Masculino , Factores de Riesgo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...